This is the accuracy figure, not the resolution. It is what the scale can be trusted to within over its length, and it is the number to compare against the positioning tolerance on your drawing. At 3 µm, a machine specified to ±5 µm still has room for the screw and the structure.
FIG. / PRODUCT VISUAL / 8 VIEWSJFT-10/40 absolute linear encoder
An absolute linear optical encoder for CNC machine tools, recorded with BiSS output, 3 µm accuracy and measuring lengths from 70 mm to 4,240 mm. Position is read absolutely, so the control knows where the axis is at power-up without a reference run.
- SeriesJFT-10/40
- Accuracy3 µm
- Max. resolution0.0025 µm
- Grating pitch40.96 µm
- Measuring length70–4,240 mm
| Encoder type | Absolute linear, optical |
|---|---|
| Output | BiSS |
| Series | JFT-10/40 |
| Accuracy | 3 µm |
| Max. resolution | 0.0025 µm |
| Grating pitch | 40.96 µm |
| Measuring length | 70–4,240 mm |
| Max. allowable speed | 180 m/min |
| Supply voltage | 5 V |
| Cable | ≤30 m; 3/6/9 m separate cable |
| Section size | 37 × 83.5 mm |
| Working temperature | 0–50 °C |
The grating repeats every 40.96 µm, and the head interpolates inside one pitch to reach 0.0025 µm. Resolution finer than accuracy does not make the axis more accurate; it makes the control smoother at low feed. Do not size a machine from the resolution figure.
The range is long enough for a gantry or a large travelling column, but the tape has to be mounted on a surface that holds its straightness over that whole length. Above roughly two metres, mounting tolerance and thermal behaviour of the machine frame dominate the 3 µm figure.
No IP rating is recorded for this model, so it is not presented for flood-coolant washdown or exposed grinding dust; the recorded working range is 0 °C to 50 °C and the supply is 5 V, which needs a regulated feed rather than a 24 V machine bus.
Does it need a reference run after power-up?
No. Absolute reading means position is known immediately at power-up, which is the reason to choose this over the incremental SGC series.
What cable length can I order?
Separate cables are recorded at 3 m, 6 m and 9 m, with a maximum of 30 m. Beyond the ordered length the signal has to be treated as a cable-extension question, not a scale question.
Is the 180 m/min figure a machining feed rate?
No. It is the maximum speed at which the reading head can travel along the scale and still produce a valid position.
Exact fit starts with the machine.
Specifications are listed with the part. Confirm machine model, interface, material and drawing before quotation.