Station pitch on a multi-station plate
The family answers one question well: which thread sizes exist. It answers almost nothing about the geometry that decides where the stations go, and that gap is the whole layout problem.
Multi-station fixturing is sold as a clamp problem and delivered as a layout problem. The clamps are the easy part: choose a size, bolt it down, repeat. What decides whether the fourth station cuts the same as the first is the distance between them, the plate that carries them, and whether that plate is allowed to move between operations. This page works through the twenty-eight records in the OK Clamp family to establish what can be settled from the catalogue and what has to be measured on the bench. Where a number is absent, the page says so instead of supplying a plausible one.
What the records fill in
Seventeen of the twenty-eight records list model options. Technical data appears in fourteen records, and every one of those fourteen reads confirm by inquiry, which is a null value wearing the name of a field. Drive mode appears ten times, fixture type seven, weight five, configuration four. Perpendicularity appears three times, parallelism twice, hardness twice, clamp type twice.
That distribution is the useful fact. The family is dense where it is easy to be dense, because a thread size is a catalogue attribute, and it is empty exactly where a layout needs numbers. A buyer who counts fields will conclude the records are rich. A buyer who tries to lay out a plate will find that the four numbers he needs are the four that were never filled.
The sizes that carry the family
Read the seventeen model-option entries together and they give fifty-six size mentions. M8 appears in thirteen records, M6 in twelve, M10 in eleven, M12 in nine, M16 in six. Then the tail: M14, M20, M24, M5 and M4 appear once each, five sizes splitting five mentions.
Four sizes therefore carry forty-five of the fifty-six mentions. That band is where a multi-station plate should live if the plate is meant to serve more than one job. A plate built around M8 accepts most of the family. A plate built around M20 accepts one record, and that record is a bench side fixture clamp whose only other stated value is a weight of one kilogram.
The distribution also explains why mixed-size plates are rare in practice. One record offers only M6 and M8. One offers only M8 to M12. One spans M8 to M24. Another spans M6 to M16 and adds a tooth option. A single plate holding an M6 clamp beside an M16 clamp needs either stepped slots or two bolt patterns, and neither arrangement is described anywhere in these records.
Two records that are not clamps
Two of the twenty-eight are a different kind of answer. One is an expansion fixture for internal support, sized D5 to D99, which holds a bore from the inside instead of clamping an outside face. The other is a quick-locking pin in D16 and D28 for welding tables, where the layout question is changeover speed rather than cutting load. Both sit in the family because they share the mounting logic, and both are stated in diameters, not thread sizes, which is why they do not appear in the size distribution above.
Series codes are a third naming system. One record lists E6, E8, E6-L and E8-L. Another lists S06 and F06. A third lists F06, S06, S08, S10 and S12. None of those codes maps to a thread size inside the records, so a buyer cannot infer a pitch or a bolt pattern from a series name. Where a code is all a record gives, the size has to be confirmed rather than reasoned about.
What a station pitch is made of
Pitch is not a clamp dimension. It is the sum of three things: the width of the clamp body, twice the clearance the fastener needs on each side, and the land the clamp bolts through on the plate. Only the first is even arguably a product attribute, and the records do not state it.
Clearance comes from the hardware chosen, not from the clamp: a nut or a socket has to be able to reach the bolt. Plate land comes from the drawing: the clamp needs enough plate around the hole to sit flat and enough edge distance not to lift. Both are decisions rather than specifications. A pitch copied from a fixture that used a different nut size is a guess that happens to be drawn to scale.
This is where the fourteen confirm-by-inquiry entries matter. Body width and body height are the two numbers that would let an engineer calculate a minimum pitch without touching the clamp. Neither is in the catalogue, so the first hour of any layout job is spent with a caliper rather than with the data.
One plate, or one base each
The second layout decision is whether the stations share a plate. A shared plate fixes the pitch permanently: once the holes are drilled, every station moves together or none of them does. Separate bases cost more plate area and more setup time, but one station can be moved, re-shimmed or removed without touching the others. On a plate that runs three jobs a week, that difference is usually worth more than the plate area it consumes.
The records do not describe either arrangement, but they do constrain the choice through mass. Four records state a weight of 0.5 kg and one states 1 kg. Those are the only masses in the family, and they are component masses, not assembly masses. A plate carrying four clamps, four workpieces and a cutting load is a different calculation, and none of the twenty-eight records contributes a number to it.

The one record that states a length
One record, the universal multiple clamp rail, lists length options of 150, 300, 400 and 500 mm. That is the only dimensional envelope in the family, and it is a rail length rather than a pitch.
Dividing a rail evenly is arithmetic, not specification. A 500 mm rail split into four equal positions gives 125 mm centre spacing; the same rail split into three gives 166 mm, which is not a number anyone would choose on purpose. Whether four positions fit at all depends on the clamp body width and the workpiece overhang, and the first of those is missing from the records. The arithmetic is still worth doing before ordering, because it tells you whether the rail under consideration is the right order of magnitude for the part.
The tolerance values that do exist
Four records carry a measured value. Perpendicularity is 0.01 mm per 100 mm in two records and 0.02 mm in a third. Parallelism is 0.005 mm per 100 mm in two. Hardness is HRC 48 to 52 in two. Those figures belong to individual components, usually the small ones: a polished nut, a measuring fixture, an integrated vise.
A layout multiplies them. A value quoted per 100 mm becomes five times that over a 500 mm rail if the error accumulates linearly, which it does not have to do but may. This is arithmetic on a stated number, not a promise about an assembly. The records do not state an assembly tolerance, and a plate that stacks four clamps does not inherit the tolerance of one clamp, because each seating face contributes its own error and the plate contributes a flatness error of its own.
Actuation, described two ways
One record is titled Pneumatic Locking OK Vise and lists its drive mode as hydraulic. A second puts pneumatic in a locking-mode field rather than a drive-mode field. A third lists drive mode as other, confirm by inquiry. Three records, three ways of answering the same question, and no force value anywhere among them.
For a multi-station plate this matters more than it looks. An actuator decides whether the stations clamp together or independently, whether a pressure failure releases the whole plate at once, and how much plumbing has to run across the fixture. A plate that clamps four stations from one circuit is fast and unforgiving; four independent circuits are slower to set and safer to lose.
What has to be measured, not looked up
Six values decide the layout and none of them is in the records: clamp body width, clamp body height, clamping stroke, station pitch, plate thickness and bolt hole pattern. Each is measurable in a few minutes with a caliper and the clamp in hand, or readable from the drawing supplied with it.
The practical order is: measure the clamp, choose the thread size from the band that carries the family, calculate the pitch from the three terms, then check the plate against the rail lengths that exist. Doing it the other way round, picking a rail and then finding clamps that fit it, is how a plate ends up with four stations and three usable ones.

Ordering a multi-station set
Four things settle the order. The thread size, taken from the band rather than the tail. The number of stations, and whether they share a plate. The plate or rail envelope, checked against the one record that states lengths. And the actuation, confirmed in writing rather than read off a title.
The records support all four decisions with the size distribution and the five weight figures. They support none of them with geometry. That is less a defect in the catalogue than a boundary: a clamp catalogue describes clamps, and a layout is a drawing. The earlier article in this family, OK clamp repeatability, takes the same records from the seating-face side, which is the other half of why a station repeats at all.
The clamps themselves are listed in multi-station OK vise and rail vise, with the model options and weights exactly as recorded, and the expansion fixture sits beside them in internal support fixture for work that has to be held from the bore.